Users Guide

NOTE: Use the Add option on the Configuration > Firmware > Catalog Management option to download the
catalog from the https://www.dell.com/support.
Updating MX7000 components using OME-Modular
1.10.20
You can upgrade the following components of MX7000 using OME-Modular 1.10.20. The following table lists the new versions of
the MX7000 components:
Table 2. MX7000OME-Modular 1.10.20 solution baselines
Component Version
iDRAC with Lifecycle Controller 4.11.11.11
Dell EMC Server BIOS PowerEdge MX740c 2.5.4
Dell EMC Server BIOS PowerEdge MX840c 2.5.4
QLogic 26XX series Fibre Channel adapters 15.05.12
QLogic 27XX series Fibre Channel adapters 15.05.12
QLogic 41xxx series adapters 15.05.14
Mellanox ConnectX-4 Lx Ethernet Adapter Firmware 14.25.80.00
Intel NIC Family Version 19.5.x Firmware for X710, XXV710,
and XL710 adapters
19.5.12
Emulex Fibre Channel Adapter Firmware. 03.02.18
OpenManage Enterprise Modular 1.10.20
MX9116n Fabric Switching Engine OS10 10.5.0.5
MX5108n Ethernet Switch OS10 10.5.0.5
MXG610s 8.1.0_lnx3
Before updating MX7000, check the PSU version. If the PSU version is 00.36.6B, then update the PSU. For details, see
https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=5tc17&oscode=naa&productcode=poweredge-
mx7000.
NOTE:
As these update instructions include updates to various components of the solution, there is a possibility of traffic
impact to existing workloads. It is recommended that the updates are applied only during a regular single maintenance
window.
NOTE: Powercycle (cold boot) of the MX7000 chassis after updating all applicable solution components may be necessary.
For details, see Controlling chassis power.
Component update order
Read the update instructions before implementing the update procedure. Collate the current versions of the
MX7000 components in your environment and note any special instructions that may be called out in the update
procedure.
Contact Dell support for assistance with upgrading the MX7000 components as it is a complex procedure. It is recommended
that you update all components within the scheduled single maintenance window.
Before proceeding with the update, review and resolve any recurring port alerts that are reported on the OME-Modular Alerts
page.
NOTE: The message ID for an operational port is NINT0001 and that for a not operational port, NINT0002.
Updating the management module firmware 13