Users Guide

8. Enable the remote RACADM session for the chassis.
You can view the remote RACADM option on the web interface only if you have the chassis administrator privilege.
NOTE: A log for remote RACADM session (login or logout) is displayed in the Audit Logs page, irrespective of the
remote RACADM status. If the remote RACADM option is disabled, the feature does not work.
NOTE: Any change in the attribute settings leads to IP drop or unavailability of the OMEModular web interface for
some time. However, the OMEModular web interface recovers automatically.
9. Click Apply to save the chassis network services settings.
Configure local access
You can configure chassis power button, quick sync, KVM, LCD, and chassis USB direct accesses for a chassis.
To configure the local access settings in a chassis:
1. Click Devices > Chassis > View Details > Settings > Local Access Configuration.
The Local Access Configuration section is expanded.
2. Select Enable Chassis Power Button to use the power button to turn the chassis off or on.
If the check box is cleared, you cannot change the power state of the chassis using the chassis power button.
3. Select the Quick Sync access type.
The available options are:
Read-onlyEnables read-only access to WiFi and Bluetooth Low Energy (BLE). You cannot write configuration
information using quick sync.
Read-writeEnables writing configuration using quick sync.
DisabledDisables reading or writing configuration through quick sync.
NOTE:
The Quick Sync feature uses a lower radio frequency (RF) power when advertising and increases the RF power
after the certificate authentication. The RF range is based on the environment and can vary.
4. Select Enable Inactivity Timeout to enable the idle timeout and enter the Timeout Limit.
Timeout is the idle time when there is no Wi-Fi traffic. Specify inactivity timeout limit, in seconds. The timeout can be
between two minutes and 60 minutes.
NOTE: The Timeout Limit option is available only if the Enable Inactivity Timeout is selected.
5. Select Enable Read Authentication to use your user credentials to read the inventory in a secure data center.
By default, this option is selected. If you clear this check box, you cannot access the secure data center.
6. Select Enable Quick Sync Wi-Fi to use WiFi to communicate with the chassis. By default, the Enable Quick Sync Wi-Fi
check box is selected.
7. Select Enable KVM Access to configure the quick sync setting using KVM. You can also use the RACADM or Redfish
command to enable or disable KVM. For more information, see the OME - Modular for PowerEdge MX7000 Chassis
RACADM CLI Guide available at www.dell.com/openmanagemanuals.
You can use the DisplayPort in the chassis to stream the video in the KVM. If the external DP to Video Graphics Array (VGA)
converter is available, you can stream the KVM video in the VGA too.
8. Select the LCD Access option for quick sync.
The available options are:
Disabled
View Only
View and Modify
NOTE: The LCD Access option is displayed only if there is a system with LCD available in the chassis.
9. In the User Defined text box, enter the text that you want to see on the LCD Home screen. The LCD Home screen is
displayed when the system is reset to factory default settings. The text can have a maximum of 62 characters and supports
a limited number of UTF-8 characters. If a UTF-8 character that is used in the text is not supported, a box is displayed
instead of the character. The default string is the service tag of the system.
10. From the LCD Language drop-down, select the language in which the text on the LCD must be displayed.
The available options are:
28
Logging in to OME-Modular