Users Guide

Table 13. Chassis DirectLED blink status and description (continued)
Error code Chassis Direct LED blink status Description and resolution
ResolutionIf the issue persists,
reattach the USB cable to the laptop or
perform and AC power cycle of the
chassis.
3 Amber The USB network link fails to come up
owing to an issue on the host laptop.
ResolutionIf the issue persists,
reattach the USB cable.
4 Turned off The USB network link is down as the
USB cable is disconnected.
ResolutionReattach the USB cable
for the link to come up.
If the Chassis Direct feature is disabled and the USB cable is inserted, the Chassis Direct LED turns amber and the alert,
USR0197, is displayed on the OME-Modular web interface. You can see the alert only if you have logged in to OME-Modular
using the public network. If you repeat the action within a short interval, the alert is not displayed. However, the Chassis Direct
LED remains amber as the MM suppresses consecutive duplicate alerts.
Configure chassis location
To configure the location of the chassis:
1. Click Devices > Chassis > View Details > Settings > Location.
The Location configuration section is expanded.
2. Enter the location names for the Data Center, Room, Aisle, and Rack.
The Data Center, Room, Aisle, and Rack support up to 128 characters.
3. Enter the number of the Rack Slot and the name of the Location where the rack is located.
The Rack Slot supports 1-255 numeric characters.
The Location supports up to 128 characters. It is supported for backward compatibility. The Data Center, Aisle, Rack, and
Rack Slot properties replace this property. Use these properties to describe the physical location of the chassis.
4. Click Apply to save the location settings.
Configure Quick Deploy settings
The Quick Deploy feature enables you to configure the password to access the iDRAC user interface, IOMs, and IPv4 and IPv6
settings. These settings can be applied to existing compute sleds or IOM devices immediately. You can apply the Quick Deploy
settings to compute sleds when they are inserted into the chassis, later. However, you cannot apply the Quick Deploy settings
to IOMs that are inserted later.
Quick deploy settings are validated when the job is run. If an invalid parameter is used, the quick deploy job fails. The Quick
Deploy job parameters are not evaluated, as they can contain any value, which is delegated while running the job.
Enabling and disabling quick deploy is a web interface feature to determine if the controls are enabled to configure Quick
Deploy settings. The back-end only processes requests from the web interface.
NOTE:
After the quick deploy settings are applied to the compute sled, the IP configuration is displayed in the OME
Modular web interface, when the inventory is refreshed.
NOTE: When IPv4 for IPv6 is disabled for FC IOMs, the Device IPv4 address or Device IPv6 address is blank on the Quick
Deploy page for IOMs. However, for network IOMs, the IPv4 and IPv6 device addresses are, :: and 0.0.0.0.
To configure the Quick Deploy settings:
1. Click Devices > Chassis > View Details > Settings > Quick Deploy.
The Quick Deploy configuration section is expanded.
30
Logging in to OME-Modular