Users Guide

Configuring OMEModular web server
1. Click Application Settings > Network > Web Server Configuration.
2. Ensure that the Enable Web Server option is selected.
3. Enter the timeout value in minutes.
4. Enter the port number for the web server.
You can enter a port number in the 10-65535 range. The default port number is 443.
when the web server https port settings from the lead chassis are applied to member chassis as part of the add or join
member task, refresh the inventory for the lead chassis manually to see the correct https port for the member chassis, on
the Hardware > Device Management Info page. Launch the member chassis from the lead chassis to see the port
number.
If you customize the https port, OME-Modular tries to redirect to the new port automatically. However, the redirection may
not work owing to security limitations of the browser. In such cases, open a new window or tab of the browser and enter the
OME-Modular URL using the customized port. For example, https://10.0.0.1:1443
NOTE: Disabling the OME-Modular web server does not affect the launching of OME-Modular GUI on the phonebook
page while using Chassis USB Direct.
NOTE: To update the webservice timeout and session configuration timeout, use the same chassis profile. Using the
same chassis profile ensures that the webservice timeout and the session configuration timeout are synchronized. Else,
when the webservice timeout is updated and the session configuration is processed, the session configuration
overwrites the web service settings.
Configuring session inactivity timeout
1. In the Universal Timeout section, select the Enable check box and enter the time in minutes after which all the sessions
must end. The duration can be in 1-1440 minutes.
If you enter the universal inactivity timeout duration, the inactivity options for the API, web interface, SSH, and Serial
sessions are disabled.
2. In the API, Web Interface, SSH, and Serial sections, enter the time in minutes after the sessions must end and the
maximum number of sessions you want to enable.
The timeout duration can be 1-1440 minutes and the maximum number of sessions can be between one and 100. The
inactivity timeout duration can be 1-100 minutes for API and Serial sessions, 1-120 minutes for web interface sessions, and
1-180 minutes for SSH sessions.
The maximum number of sessions for the interfaces are as follows:
API1-100
Web interface1-6
SSH1-4
Serial1
When you downgrade from the current version of OME-Modular to an earlier version, maximum number of API sessions
supported is 32. However, if you upgrade OME-Modular to the latest version that supports 100 sessions, but the API Session
attribute value that is displayed is 32. You can manually set the attribute value to 100 sessions.
Configuring OMEModular date and time settings
1. Click Application Settings > Network > Time Configuration.
2. Select the Use NTP check box, if required, and enter the NTP server details.
3. Select the required time zone.
NOTE:
Any change in the attribute settings leads to IP drop or unavailability of the OMEModular web interface for
some time. However, the OMEModular web interface recovers automatically.
44 Logging in to OME-Modular