Monitoring SFP Transceiver devices using web interface
To view theSFP Transceiver device information using Web interface, go to System > Overview > Network Devices and click
on particular device. For more information about the displayed properties, see iDRAC Online Help.
The page name also displays the slot number where the transceiver device is available under Port statistics.
Monitoring SFP Transceiver devices using RACADM
To view the SFP Transceiver device information using RACADM, use the hwinventory command.
For more information, see the iDRAC RACADM CLI Guide available at https://www.dell.com/idracmanuals.
Telemetry Streaming
Telemetry enables users to collect and stream real-time device metrics, events, and data logs from a PowerEdge server to a
subscribed external client or server application. Using Telemetry, you can set the type and frequency of reports that needs to be
generated.
NOTE: The feature is supported on all the platforms and it requires iDRAC Datacenter license.
Telemetry is one-to-many solution for collecting and streaming the live system data from one or more PowerEdge servers
(iDRAC) to a centralized 'Remote Server Monitoring, Analysis, and Alerting service'. The feature also supports on-demand data
collection of the data.
The telemetry data includes metrics/inventory and logs/events. The data can be streamed (pushed out) or collected (pulled)
from iDRAC to or by remote consumers like Redfish client and Remote Syslog Server. The telemetry data is also provided to
the iDRAC SupportAssist data collector on demand. The data collection and report is based on predefined Redfish telemetry
metrics, trigger, and report definitions. The telemetry streaming settings can be configured through RACADM, Redfish, and
Server Configuration Profile (SCP).
To configure Telemetry, enable or select the required device reports or logs that define the behavior and frequency of data
streaming. Go to Configuration > System Settings page to configure Telemetry. Data streaming is automatic until the
Telemetry is disabled.
Following table describes the metric reports that can be generated using telemetry:
Type
Metric Group Inventory Sensor Statistics Configuration Metrics
I/O Devices NICs No Yes Yes No No
FC HBAs No Yes Yes No No
Server Devices CPUs No Yes No No Yes
Memory No Yes No No Yes
Fans No Yes No No No
PSUs No No No No Yes
Sensors No Yes No No No
Environmental Thermal No Yes No No Yes
Power No No Yes No Yes
Performance No No Yes No No
Accelerators GPUs No No Yes No Yes
To know about the field descriptions of Telemetry section, see iDRAC Online Help.
NOTE:
StorageDiskSMARTDATA is only supported on SSD drives with SAS/SATA bus protocol and behind the BOSS controller.