Owners Manual
Table Of Contents
- Dell PowerEdge R430 Owner's Manual
- Dell PowerEdge R430 system overview
- Supported configurations for the PowerEdge R430 system
- Front panel
- Back panel features
- Diagnostic indicators
- Locating service tag of your system
- Documentation resources
- Technical specifications
- Initial system setup and configuration
- Pre-operating system management applications
- Options to manage the pre-operating system applications
- System Setup
- Viewing System Setup
- System Setup details
- System BIOS
- Viewing System BIOS
- System BIOS Settings details
- Boot Settings
- Network Settings
- System Security
- System Information
- Memory Settings
- Processor Settings
- SATA Settings
- Integrated Devices
- Serial Communication
- System Profile Settings
- Miscellaneous Settings
- iDRAC Settings utility
- Device Settings
- Dell Lifecycle Controller
- Boot Manager
- PXE boot
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Front bezel (optional)
- System cover
- Inside the system
- Cooling shroud
- System memory
- Hard drives
- Removing a 2.5-inch hard drive blank
- Installing a 2.5-inch hard drive blank
- Removing a 3.5-inch hard drive blank
- Installing a 3.5-inch hard drive blank
- Removing a 3.5-inch cabled hard drive carrier
- Installing a 3.5-inch cabled hard drive carrier
- Removing a hot swappable hard drive carrier
- Installing a hot swappable hard drive carrier
- Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier
- Installing a 3.5-inch hard drive adapter into a hot swap hard drive carrier
- Removing a 2.5-inch hard drive from a 3.5-inch hard drive adapter
- Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter
- Removing a hard drive or a solid state drive from a hard drive carrier
- Installing a hard drive or solid state drives into a hard drive carrier
- Optical drive (optional)
- Cooling fans
- Internal USB memory key (optional)
- Expansion cards and expansion card riser
- iDRAC port card (optional)
- SD vFlash card (optional)
- Internal dual SD module (optional)
- Integrated storage controller card
- Processors and heat sinks
- Power supply units
- System battery
- Hard-drive backplane
- Control panel
- Power interposer board
- System board
- Trusted Platform Module
- Using system diagnostics
- Jumpers and connectors
- Troubleshooting your system
- Troubleshooting system startup failure
- Troubleshooting external connections
- Troubleshooting the video subsystem
- Troubleshooting a USB device
- Troubleshooting a serial input and output device
- Troubleshooting a NIC
- Troubleshooting a wet system
- Troubleshooting a damaged system
- Troubleshooting the system battery
- Troubleshooting power supply units
- Troubleshooting cooling problems
- Troubleshooting cooling fans
- Troubleshooting system memory
- Troubleshooting an internal USB key
- Troubleshooting a micro SD card
- Troubleshooting an optical drive
- Troubleshooting a drive or SSD
- Troubleshooting a storage controller
- Troubleshooting expansion cards
- Troubleshooting processors
- System messages
- Getting help
1. Remove the cooling shroud.
Steps
1. Loosen the screws that secure the integrated storage controller cable to the integrated storage controller card connector on
the system board.
2. Lift the integrated storage controller cable away from the integrated storage controller.
3. Lift one end of the card and angle it to disengage the card from the integrated storage controller card holder on the system
board.
4. Lift the card out of the system.
Figure 63. Removing the integrated storage controller card
1.
integrated storage controller cable 2. integrated storage controller card
3. integrated storage controller card connector on the
system board
4. integrated storage controller card holder
Next steps
1. Install the cooling shroud.
2. Installing the integrated storage controller card.
Related references
Safety instructions on page 71
Related tasks
Before working inside your system on page 72
Removing the cooling shroud on page 79
Installing the cooling shroud on page 80
Installing the integrated storage controller card on page 127
After working inside your system on page 72
126
Installing and removing system components