Table 34. Expanded operating temperature specifications (continued)
Expanded operating temperature Specifications
For temperatures between 35°C and 40°C, de-rate maximum
allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F
per 319 ft).
< 1% of annual operating hours 5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate down to 5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum
allowable temperature by 1°C per 125 m above 950 m (1°F per 228
ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD
panel and in the System Event Log.
Expanded operating temperature restrictions
Processors of 55 W and 65 W are not supported.
Do not perform a cold startup below 5°C.
Allow processor performance degrade.
Non-redundant power supplies are not supported.
Non Dell qualified peripheral cards and/or peripheral cards are not supported.
Maximum altitude for the operating temperature must be 3050 m (10,000 ft).