Manual

36 About Your System
E201C SMI
initializati
on failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E201D Shutdown test
failure.
Power cycle
AC.
BIOS shutdown test failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 169.
If the problem persists,
see "Getting Help" on
page 195.
E2020 CPU
configuratio
n failure.
Check screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processors" on page 178.
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 169.
E2022 General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
Code Text Causes Corrective Actions
book.book Page 36 Thursday, February 18, 2010 2:06 PM