Instruction Manual

140 Troubleshooting
Some configured disks
have been removed from
your system or are no
longer accessible.
Check your cables and
ensure all disks are
present. Press any key
or ’C’ to continue.
The message indicates that
some configured disks were
removed. If the disks were
not removed, they are no
longer accessible.
The SAS cables for your
system might be
improperly connected.
Check the cable
connections and restart
the system.
If there are no cable
problems, press any key
or <C> to continue.
The battery is
currently discharged
or disconnected.
Verify the connection
and allow 30 minutes
for charging.If the
battery is properly
connected and it has
not returned to
operational state
after 30 minutes of
charging then contact
technical support for
additional assistance.
NOTE: This message may
appear for controller
without battery, depending
on the virtual disks’ policies.
The controller
battery is missing or
currently
inaccessible. Contact
Dell Technical
Support if the issue
persist after 30
minutes.
The controller
battery is completely
discharged and
needs to be charged
for it to become
active. You must first
charge the battery,
then wait for a few
minutes for the
system to detect it.
Table 9-1. BIOS Errors and Warnings
(continued)
Error Message Probable Cause Corrective Action
PERC7.2_UG.book Page 140 Thursday, March 3, 2011 2:14 PM