CLI Guide

-name <VD name>—Specifies the name of the virtual disk.
-size <VD size>—Specifies the size of each virtual disk.
b—Specifies the size in bytes
k—Specifies the size in kilobytes
m—Specifies the size in megabytes
g—Specifies the size in gigabytes
t—Specifies the size in terabytes
-sc—Number of spans in a virtual disk (required for multi-span
RAID level).
NOTE:
For PERC9, if the value of
controller.SupportRAID10UnevenSpans is
supported, you can enter only 0 for this option
while creating RAID level 10. The created RAID10
virtual disk displays the spandepth as 1 (default).
For other controllers:
The default value for multi-span RAID levels is
2 and for basic RAID level is 1.
For hybrid RAID levels such as RAID10,
RAID50, and RAID60, this option is mandatory.
The value for-sc option can be 0 only for
RAID10.
-T10PIEnable—Creates a virtual disk with protection
information.
-key <Key id>—Specifies the key id.
-passwd <passphrase>—Specifies the passphrase.
-newpasswd <passphrase>—Specifies the new
passphrase.
-assign {yes | no}—Assigns or unassigns the disk as a
hotspare.
-type { ghs | dhs}—Assigns a global or dedicated
hotspare.
-vdkey:<VD FQDD>—Assigns the dedicated hotspare to the
specified virtual disk. This option is required for dedicated
hotspare.
-state <start|stop>start value starts a patrol read
operation.
stop value stops a running patrol read operation.
NOTE:
To start the operation, the
Controller.PatrolReadMode must be in Manual
mode.
-dstpd-replaces a physical disk in virtual disk configuration.
-vd-virtual disk fqdd to make it as a bootable drive.
-speed—Specifies the initialization of the Virtual disk.
fast—Performs fast initialization.
full—Performs slow initialization.
blink: <FQDD> or unblink: <FQDD><FQDD> can be
physical disk drives, virtual disks, or PCIeSSD.
<PCIeSSD FQDD>—Specifies the PCIeSSD FQDD.
<PCIeSSD controller|enclosure FQDD>—Specifies
the PCIeSSD controller or enclosure FQDD.
preparetoremove—Specifies the PCIeSSD drive to prepare
for removal.
126
RACADM Subcommand Details