CLI Guide

System.Power.PFCEnable (Read or Write)
Table 456. Details of System.Power.PFCEnable
Description
Enables the power factor correction enable.
NOTE:
This object is supported only for iDRAC on Rack and Tower servers.
This object is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.RedundancyCapabilities (Read Only)
Table 457. Details of System.Power.RedundancyCapabilities
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask indicates the values that are set to
cfgSensorRedundancyPolicy.
NOTE: This object is not applicable for iDRAC on Blade servers.
Legal Values
0 — not applicable
1 — Non-Redundant
2 — 1+1 Redundant
4 — 2+1 Redundant
8 — 2+2 Redundant
16 — 3+x Redundant
32 — 4+x Redundant
64 — 5+x Redundant
Default Value
0 — not applicable
Write Privilege Not Applicable
License Required Not Applicable
Dependency Not Applicable
System.Power.RedundantState (Read Only)
Table 458. Details of System.Power.RedundantState
Description
Retrieves the redundancy state for the chassis.
NOTE: This object is not applicable for Rack and Tower server.
Legal Values
0 — None
1 — Full
Database Objects With Get and Set Commands 255