CLI Guide

Dependency
None
System.ServerOS.ServerPoweredOnTime (Read Only)
Table 473. Details of System.ServerOS.ServerPoweredOnTime
Description Indicates the time (in seconds) from when the operating system is turned ON.
Legal Values Any integer value indicating the system powered on time duration.
Default Value 0
Write Privilege Configure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalSettings
This group provides information about the thermal settings of the server.
To know more about the platforms supported for AirExhaustTemp and FanSpeedOffset settings, see the iDRAC User's Guide available
at www.dell.com/esmmanuals.
System.ThermalSettings.AirExhaustTemp (Read or Write)
Table 474. Details of System.ThermalSettings.AirExhaustTemp
Description Displays the air exhaust temperature and sets the exhaust temperature to any appropriate value.
NOTE: This attribute is platform dependent.
Legal Values
0 — 40°C
1 —45°C
2 — 50°C
3 — 55°C
255 — None
Default value 255 — None
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalSettings.BaseAlgorithm (Read or Write)
Table 475. Details of System.ThermalSettings.BaseAlgorithm
Description Specifies the thermal base algorithm.
NOTE: This object is not applicable for Rack and Tower server.
Legal Values
0 — Auto
1 — Max Exhaust Temperature
2 — Min Power
Default values None
License Required iDRAC Express
Dependency None
260 Database Objects With Get and Set Commands