CLI Guide

Input
racadm> cd..
Output To traverse back to the previous directory, use the command.
Example
Example 1: To traverse back from power to system object:
Input: racadm/power> cd..
Output:
system>>
Example 2: To traverse back from system object to the prompt:
Input: racadm/system> cd..
Output:
racadm>>
clearasrscreen
Table 9. Details of clearasrscreen
Description
Clears the last crash (ASR) screen that is in memory.
For more information, see "Enabling Last Crash Screen" section in the iDRAC User’s Guide.
NOTE: To run this subcommand, you must have the Clear Logs permission.
Synopsis
racadm clearasrscreen
Input
None
Output
Clears the last crash screen buffer.
Example
racadm clearasrscreen
clearpending
Table 10. Details of clearpending
Description Deletes the pending values of all the attributes (objects) in the device (NIC, BIOS, FC, and Storage).
NOTE: If any attribute is not modified or a job is already scheduled for the same device, then the
pending state is not cleared or deleted.
Synopsis
racadm clearpending <FQDD>
Input <FQDD> — The values are:
BIOS FQDD
NIC FQDD
FC FQDD
Storage controller FQDD
<FQDD>: The values are:
BIOS.Setup.1–1
NIC.Integrated.1–1
RAID.Integrated.1–1
48 RACADM Subcommand Details