CLI Guide

NOTE: These commands specifically apply to an active-CMC update.
Signed CMC Firmware Image:
To get the firmware update status:
racadm fwupdate –s –m cmc-active
Invalid firmware: The uploaded firmware image does not contain a verification signature.
Table 21. Firmware update methods on Blade, Rack and Tower servers
FW Update Method iDRAC on Blade Servers iDRAC on Rack and Tower Servers
Local RACADM Yes Yes
Local RACADM-TFTP Yes Yes
Local RACADM-FTP Yes Yes
Remote RACADM Yes Yes
Remote RACADM-TFTP Yes Yes
Remote RACADM-FTP Yes Yes
Firmware RACADM-TFTP Yes Yes
Firmware RACADM-FTP Yes Yes
Table 22. Firmware update methods on CMC servers
FW Update Method CMC
Local RACADM No
Local RACADM-TFTP No
Local RACADM-FTP No
Remote RACADM Yes
Remote RACADM-TFTP Yes
Remote RACADM-FTP Yes
Firmware RACADM-TFTP Yes
Firmware RACADM-FTP Yes
get
Table 23. Details of get
Description
Displays the value of one or more objects. The getsub-command has two forms.
Displays the value of a single object.
Exports the value of multiple objects to a file.
It supports multiple object value export in two file formats
JSON format— SCP JSON files can be exported to a network share file.
INI format — The INI format files can be exported to a local file only
60 RACADM Subcommand Details