CLI Guide

4 23:09:40 idrac8 L4, S3 [10297]: ret is 0
4 23:09:40 idrac8 L4, S3 [10297]: probename is Chassis Controller
4 23:09:40 idrac8 L4, S3 [10297]: pCMCStatusobj->offsetKey is 24
4 23:09:40 idrac8 L4, S3 [10297]: pCMCStatusobj->sensorValue is 0
4 23:09:40 idrac8 L4, S3 [10297]: MAP Uninitialized, time to uninit = 0 millisec
4 23:09:40 idrac8 L4, S3 [10297]: RACADM total execution time: 1680 milliseconds
Table 44. Battery sensor
<Sensor Name> <Status> <Reading> <lc> <uc>
System Board CMOS
Battery
Ok Present NA NA
PERC1 ROMB Battery Ok Unknown NA NA
PERC2 ROMB Battery Ok Unknown NA NA
Table 45. PERFOMANCE sensor
<Sensor Name> <Status> <Status> <lc> <uc>
System Board Power
Optimized
Ok Not Degraded NA NA
Table 46. INTRUSION sensor
<Sensor Name> <Intrusion> <Status>
System Board Intrusion Closed Power ON
Table 47. REDUNDANCY sensor
<Sensor Name> <Status> <Type>
System Board Fan Redundancy Full Redundant Fan
System Board PS Redundancy Disabled PSU
Table 48. SYSTEM PERFORMANCE sensor
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc> [R/W] <unc> [R/W]
System Board
CPU Usage
Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board
IO Usage
Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board
MEM Usage
Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board
SYS Usage
Non-Critical 0% 0% 100% 0% [N] 99% [Y]
getssninfo
Table 49. Details of getssninfo attribute
Description
Displays a list of users that are connected to iDRACCMC. The following information is displayed:
Session ID
Username
IP address (if applicable)
Session type (for example, serial or Telnet)
Login date and time in MM/DD/YYYY HH:MM:SS format
RACADM Subcommand Details 75