CLI Guide

NOTE: The host name and OS Name fields in the getsysinfo output display accurate information
only if the Dell OpenManage Server Administrator is installed on the managed system. Else, these
fields may be blank or inaccurate. An exception to this are VMware operating system names, which
are displayed even if the Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-A] [-c] [-4] [-6]
Input
—4 — Displays IPv4 settings
—6 — Displays IPv6 settings
—c — Displays common settings
—d — Displays iDRAC information
—d — Displays CMC information
—A — Eliminates the printing of headers or labels
Output
racadm getsysinfo
CMC Information:
CMC Date/Time = Wed Sep 17 2014 23:13
Primary CMC Location = CMC-1
Primary CMC Version = 5.00
Standby CMC Version = 5.00
Last Firmware Updated = Tue Sep 16 2014 22:11
Hardware Version = A09
CMC Network Information:
NIC Enabled = 1
MAC Address = 78:2B:CB:46:5C:8A
Register DNS CMC Name = 1
DNS CMC Name = cmc-effort
Current DNS Domain = cmc.com
VLAN ID = 1
VLAN Priority = 0
VLAN Enabled = 0
CMC IPv4 Information:
IPv4 Enabled = 1
Current IP Address = 192.168.0.10
Current IP Gateway = 192.168.0.10
Current IP Netmask = 255.255.255.0
DHCP Enabled = 1
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
CMC IPv6 Information:
IPv6 Enabled = 0
Autoconfiguration Enabled = 0
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6 = 0
Chassis Information:
System Model = PowerEdge M1000e
System AssetTag = 12345678901234567890123456781234456771234567890asvcdefrtghyhytg
Service Tag = JGB6B2S
Chassis Name = CMC-JGB6B2S
Chassis Location = 3rdflor
RACADM Subcommand Details