Users Guide

Operating
System
Firewall
Status
Avahi Package nss-mdns Package
RHEL 5.9
32–bit
Disable Install as a separate package
(avahi-0.6.16-10.el5_6.i386.rpm)
Install as a separate package (nss-
mdns-0.10-4.el5.i386.rpm)
RHEL 6.4
64–bit
Disable Install as a separate package
(avahi-0.6.25-12.el6.x86_64.rpm)
Install as a separate package (nss-
mdns-0.10-8.el6.x86_64.rpm)
SLES 11 SP3
64–bit
Disable Avahi package is the part of operating
system DVD
nss-mdns is installed while installing
Avahi
On the host system, while installing RHEL 5.9 operating system, the USB NIC pass-through mode is in
disabled state. If it is enabled after the installation is complete, the network interface corresponding to the
USB NIC device is not active automatically. You can do any of the following to make the USB NIC device
active:
Configure the USB NIC interface using Network Manager tool. Navigate to SystemAdministrator
NetworkDevicesNewEthernet Connection and select Dell computer corp.iDRAC Virtual
NIC USB Device. Click the Activate icon to activate the device. For more information, see the RHEL
5.9 documentation.
Create corresponding interface’s config file as ifcfg-ethX in /etc/sysconfig/network-script/ directory.
Add the basic entries DEVICE, BOOTPROTO, HWADDR, ONBOOT. Add TYPE in the ifcfg-ethX file and
restart the network services using the command service network restart.
Reboot the system.
Turn off and turn on the system.
On systems with RHEL 5.9 operating system, if the USB NIC was disabled and if you turn off the system or
vice-versa, when the system is turned on and if the USB NIC is enabled, the USB NIC device is not active
automatically. To make it active, check if any ifcfg-ethX.bak file is available in the /etc/sysconfig/network-
script directory for the USB NIC interface. If it is available, rename it to ifcfg-ethX and then use the ifup
ethX command.
Related Links
Installing VIB file
Installing VIB file
For vSphere operating systems, before enabling the USB NIC, you must install the VIB file.
To install the VIB file:
1. Using Win-SCP, copy the VIB file to /tmp/ folder of the ESX-i host operating system.
2. Go to the ESXi prompt and run the following command:
esxcli software vib install -v /tmp/ iDRAC_USB_NIC-1.0.0-799733X03.vib --no-
sig-check
The output is:
Message: The update completed successfully, but the system needs to be
rebooted for the changes to be effective.
Reboot Required: true
VIBs Installed: Dell_bootbank_iDRAC_USB_NIC_1.0.0-799733X03
VIBs Removed:
VIBs Skipped:
3. Reboot the server.
4. At the ESXi prompt, run the command: esxcfg-vmknic –l.
102