Users Guide

Convert to non-RAID disk (supported only in RACADM and is a staged operation)
Blink or unblink the LED
Related Links
Inventorying and monitoring storage devices
Assigning or unassigning physical disk as global hot spare
Assigning or unassigning physical disk as global hot spare
A global hot spare is an unused backup disk that is part of the disk group. Hot spares remain in standby
mode. When a physical disk that is used in a virtual disk fails, the assigned hot spare is activated to replace
the failed physical disk without interrupting the system or requiring your intervention. When a hot spare is
activated, it rebuilds the data for all redundant virtual disks that were using the failed physical disk.
NOTE: From iDRAC v2.30.30.30 or later, you can add global hot spares when virtual disks are not
created.
You can change the hot spare assignment by unassigning a disk and choosing another disk as needed.
You can also assign more than one physical disk as a global hot spare.
Global hot spares must be assigned and unassigned manually. They are not assigned to specific virtual
disks. If you want to assign a hot spare to a virtual disk (it replaces any physical disk that fails in the virtual
disk), then see Assigning or unassigning dedicated hot spares.
When deleting virtual disks, all assigned global hot spares may be automatically unassigned when the last
virtual disk associated with the controller is deleted.
If you reset the configuration, the virtual disks are deleted and all the hot spares are unassigned.
You must be familiar with the size requirements and other considerations associated with hot spares.
Before assigning a physical disk as a global hot spare:
Make sure that Lifecycle Controller is enabled.
If there are no disk drives available in ready state, insert additional disk drives and make sure that the
drives are in ready state.
If no virtual disks are present, create at least one virtual disk.
If physical disks are in non-RAID mode convert them to RAID mode using iDRAC interfaces such as
iDRAC web interface, RACADM, or WS-MAN, or <CTRL+R>.
If you have assigned a physical disk as a global hot spare in Add to Pending Operation mode, the pending
operation is created but a job is not created. Then, if you try to unassign the same disk as global hot
spare, the assign global hot spare pending operation is cleared.
If you have unassigned a physical disk as a global hot spare in Add to Pending Operation mode, the
pending operation is created but a job is not created. Then, if you try to assign the same disk as a global
hot spare, the unassign global hot spare pending operation is cleared.
Assigning or unassigning global hot spare using web interface
To assign or unassign a global hot spare for a physical disk drive:
1. In the iDRAC web interface, go to Overview StoragePhysical DisksSetup.
229