Users Guide

support.dell.com PowerVault 51F Commands 4-31
syslogdIp
The
syslogdIp
command sets or displays the switches system log daemon IP
address. The command syntax is
syslogdip <
ip address
>.
tempShow
The following example shows the
tempShow
command screen, which shows the
switchs temperature as measured by five sensors on the system board.
Port state The port state follows the GBIC type. The possible port states
include:
No_Card — No card present in this switch slot
No_Module — No GBIC module in this port
No_Light — The module is not receiving light
No_Sync — The module is receiving light but is out of
sync
In_Sync — The module is receiving light and is in sync
Laser_Flt — The module is signaling a laser fault (defec-
tive GBIC)
Port_Flt — The port has been marked faulty (defective
GBIC, cable, or device)
Diag_Flt — The port failed diagnostics (defective G_Port
or FL_Port card or system board)
Online — The port is up and running
Lock_Ref — The port locking to the reference signal
Testing — Running diagnostics
Comment field The comment field follows the port state. The possible com-
ments include:
Disabled
The port is disabled
Loopback
The port is in loopback mode
E_Port
The WWN and switch name of the other
switch is shown, the use of this Inter Switch Link (ISL) is
shown (see FC_SW)
F_Port
The WWN of the N_Port is shown
G_Port
The port is online but is not yet an E_Port or
F_Port
L_Port
The port is connected to an arbitrated loop
Table 4-16. switchShow Command Field Descriptions
(continued)
Field Description