Users Guide

A-2 Dell PowerVault 56F 16-Port Fibre Channel Switch User’s Guide
DELL CONFIDENTIAL - Preliminary 4/11/00
(Rev. 11/3/98) FILE LOCATION: S:\SYSTEMS\Labrador\Ug\89TMRaa0.fm

User interface . . . . . . . . . . . . . . . RJ45 front panel connector for
10/100BASE-T Ethernet or in-band
Front panel controls . . . . . . . . . . Controls with an LCD for configuring the
switch and monitoring status and
diagnostics
Gigabit interface converters (GBIC)
module . . . . . . . . . . . . . . . . . . . . Copper GBIC module based on High-Speed
Serial Data Connection (HSSDC) interface
standards.
Female HSSDC connector. Cables of 1, 6,
and 12 meters (m) currently qualified. Stan-
dard cables with HSSDC-to-DB9 male
connectors are also available.
Optical port . . . . . . . . . . . . . . . . . Uses a shortwave (780 to 850 nanometer
[nm]) or long wavelength (1270 to 1350 nm)
laser transmitter.
Laser complies with 21 CFR, subpart (J)
Class 1-laser safety requirements. Uses
non-open Fibre Control (OFC) optical GBICs
in the switch circuit. Class 1 laser limits opti-
cal power emitted by the port to allow safe
operation, eliminating the need for physical
shutters. The optical GBIC uses the duplex-
subscriber connector (SC) scheme.

Input voltage. . . . . . . . . . . . . . . . 85 to 265 volts AC (VAC)
Total input power . . . . . . . . . . . . 155 watts (W)
(with one or two power supplies)
Input line frequency . . . . . . . . . . 47 to 63 hertz (Hz)
Local country power cable supplied.

Rack Mount (2U):
Height . . . . . . . . . . . . . . . . . . 8.73 centimeters (cm) (3.44 inches)
Width. . . . . . . . . . . . . . . . . . . 42.9 cm (16.88 inches)
Depth. . . . . . . . . . . . . . . . . . . 72.4 cm to 73.9 cm (28.5 to 29.1 inches)
Weight . . . . . . . . . . . . . . . . . . 12.9 kilograms (kg) (28.5 pounds [lb])
