Users Guide

Using PowerVaultâ„¢ 50F Fibre Channel Switch Manager: Dellâ„¢ PowerVaultâ„¢ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/USING.HTM[3/15/2013 11:32:00 AM]
green
Port Detail View Page
The Port Detail View Page features eight cascaded folders. Each folder has a tab on the top to show the
port number and a status light to tell the port state (disabled or enabled with the same light as described in
Table 6-3). The port information is updated once per second. However, the time interval may be as long as
2.5 seconds depending on the browser used. By monitoring the eight tabs, a system administrator can
evaluate each port state. The default top folder displayed on this page is for the port number checked from
the General Switch View Page. Clicking a tab brings the corresponding port folder to the front.
Below the folders is a pushbutton linked to the Administrative Interface Page (see "Administrative Interface
Page" for more information) where port enable/disable can be performed. A pushbutton is linked to the
Performance View Page (see "Performance View Page
" for more information) where port and switch
throughput data is plotted. A Done pushbutton is used to exit from the page.
Each port folder contains general port status information such as the port number, port type (E-Port, G-
Port), port WWN name, and some detailed information, such as the number of interrupts, number of link
failures, number of parity errors, number of time-outs, and the size of free buffer.
The LED located in the upper-right corner in each tab resembles the port LED in the switch front panel.
Table 6-4. Port Detail View Page Fields
Field Description
Port Number The port number
Port Status The port state follows the GBIC type. The possible port states include:
No_Card - No card present in this switch slot
No_Module - No GBIC module in this port
No_Light - The module is not receiving signal
No_Sync - The module is receiving light but is out of sync
In_Sync - The module is receiving light and is in sync
Laser_Flt - The module is signaling a laser fault (defective GBIC)
Port_Flt - The port has been marked faulty (defective GBIC, cable, or device)
Diag_Flt - The port failed diagnostics (defective G_Port or FL_Port card or motherboard)
Online - The port is up and running
Lock_Ref - The port locking to the reference signal
Port Type The port type (E_Port, G_Port or FL_Port).
Port Module (or GBIC Module) The GBIC type follows the port number. The four GBIC types include:
- - no GBIC present
sw - shortwave GBIC
lw - longwave GBIC
cu - copper GBIC
Port Worldwide Name The Worldwide Name for this port.
Interrupts Total number of interrupts.
Unknown Number of unknown interrupts.
Lli Number of low level interface (LLI) interrupts.
Proc_rqrd Number of interrupts with processing (CPU) required.
Timed_out Number of timed out interrupts.