Users Guide

PowerVault™ 50F Commands: Dell™ PowerVault™ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/COMMANDS.HTM[3/15/2013 11:32:02 AM]
version
The version command fields are described in Table 7-9.
Table 7-9. version Command Field Descriptions
Field Description
VxWorks
version
VxWorks operating environment version used on the processor
Firmware
version
Firmware version
Made on
Firmware release date and time
diagHelp
The diagHelp command displays the diagnostic help commands available for troubleshooting switch
problems (see "Diagnostic Commands").
licenseHelp
The PowerVault™ 50F Switch is shipped with licenses enabled. These license commands are provided in
the event that software upgrades are made available in the future.
routeHelp
Route commands are not currently supported by Dell.
Diagnostic Commands
Diagnostic commands enable you to monitor, test, and evaluate the switch.
centralMemoryTest
Figure 7-15 shows the centralMemoryTest command, which is used to check the motherboard's memory. A
diagnostic pattern is written and read from memory to ensure that all memory is functioning properly.
This command may not be executed on an operational switch. Before issuing
centralMemoryTest, disable the switch using the switchDisable command.
Figure 7-15. centralMemoryTest Command Example
If the test does not detect an error there is no output. If an error is detected one of the following messages
are displayed: