Port N regname error counter is nnnn sb 0
Probable cause: Failure of G_Port and FL_Port ASIC
Action: Replace the switch
Probable cause: Failure of interface module
Action: Replace the switch
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module
DIAG-TIMEOUT, 1
Port N receive timeout.
Probable cause: Failure of G_Port and FL_Port ASIC
Action: Replace the switch
Probable cause: Failure of interface module
Action: Replace the switch
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module
DIAG-DATA, 1, PortX:pass nn
Frame Tx4>->Rx4 payload byte offset nn is 0xXX sb 0xXX
(CMEM: SOF@ bufline/offset 0xXXXX/0xXX, error @ physical 0xXXXX/0xXX
Only one bad byte -- or -- Last bad byte at offset nn.
Probable cause: Failure of motherboard
Action: Replace the switch
Probable cause: Failure of interface module
Action: Replace the switch
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module
DIAG-STATS, 1
(regname) counter wrong on port nn, is nn sb nn
Probable cause: Failure of G_Port and FL_Port ASIC
Action: Replace the switch
Probable cause: Failure of Interface module
Action: Replace the switch
DIAG-INIT, 1, portLB: pass nn
Port N failed to go active after initialization
Probable cause: Failure of G_Port and FL_Port ASIC
Action: Replace the switch
Probable cause: Failure of interface module
Action: Replace the switch
Probable cause: Failure of GBIC module connector
Action: Replace GBIC module