Users Guide

Error Messages: Dellâ„¢ PowerVaultâ„¢ 50F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
file:///C|/Users/sharon_anand/Desktop/PowerVault/50f_enit/ERROR.HTM[3/15/2013 11:32:10 AM]
To display error messages via Telnet:
1. From the prompt, enter errShow command.
2. To scroll through the error list, type <CR>
3. Scroll through error log (if no errors encountered, the command returns "No Error").
Error Messages by Firmware Module
Table A-1 shows the error messages organized by module.
Table A-1. Errors
Module
Error
Severity Explanation Action
Flood INVLSR (3) An unknown Link State Record has
been received from a neighbor
switch.
Check that all paths and routing tables are correct using the
commands uPathShow <domain>, or uPathAllShow. If the
paths are not correct reboot the neighbor switch that sent the
wrong data.
Check the paths and routes again. If they are still incorrect,
reboot the local switch.
LSRLEN (2) The local switch is trying to create
a Link State Update that exceeds
the maximum length.
Check that all paths and routing tables are correct. If they are not,
reboot the local switch.
FSPF BADSRC (3) The neighbor switch domain ID has
changed, without the link going
down.
The system automatically recovers.
INPORT (2) The input port in the IU received by
the path selection task is out of
range.
Check that all paths and routing tables are correct. If they are not
correct, reboot the local switch.
MSG (2) The path selection task has
received an unknown message
from another task.
Check that all paths and routing tables are correct. If they are not,
reboot the neighbor switch.
Check the paths and routes again. If they are still incorrect,
reboot the local switch.
REMDOMAIN
(2)
The message received from a
neighbor switch has a source
domain ID out of range.
Check that all paths and routing tables are correct. If they are not,
reboot the neighbor switch.
Check the paths and routes again. If they are still incorrect,
reboot the local switch.