Owners Manual

30 About Your System
E2111 SBE Log
Disable Crd #
DIMM ##
The system BIOS has
disabled memory single-bit
error (SBE) logging, and
will not resume logging
further SBEs until the
system is rebooted. "##"
represents the DIMM
implicated by the BIOS. If
no memory riser card is
present, the "Crd #" string
is left out of the message.
See "Troubleshooting
System Memory" on
page 142.
E2112 Mem Spare Crd
# DIMM ##
The system BIOS has
spared the memory
because it has determined
that the memory had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 142.
E2113 Mem Mirror
Crd # DIMM ##
& ##
The system BIOS has
disabled memory
mirroring because it has
determined that one half
of the mirror has had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 142.
E2118 Fatal NB Mem
CRC
One of the connections in
the Fully Buffered DIMM
(FBD) memory subsystem
link on the Northbound
side has failed.
See "Troubleshooting
System Memory" on
page 142.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 30 Monday, September 14, 2009 12:57 PM