User Manual

Back to Contents Page
Maximum wet bulb temperature
26°C(79°F)
Internal Drive
Physical Specifications
Width (without bezel)
146.0 mm (5.75 in)
Width (with bezel)
148.0 mm (5.83 in)
Length (without bezel)
205.0 mm (8.09 in)
Length (with bezel)
210.0 mm (8.29 in)
Height (without bezel)
41.0 mm (1.63 in) without bezel
Height (with bezel)
42.7 mm (1.69 in) with bezel
Weight (without a cartridge)
1.61 kg (3 lb 9 oz)
Power Supply Requirements
Tolerance
+ 5 VDC and + 12 VDC (plus or minus 10%)
Steady State Current for 5 VDC
1.9 A minimum/3.4 A maximum
Steady State Current for 12 VDC
0.2 A minimum/1.1 A maximum
Peak supply current for 5 VDC
3.6 A for 100 ms (18 W)
Peak supply current for 12 VDC
4.1 A for 2 ms (49.2 W)
Power Usage
Idle mode with no cartridge
6.5 W
Idle mode with a cartridge loaded
6.5 W
Reading and writing at 5.46 m/s
24 W
Performance
Interfaces
6Gb SAS
Recording format
LTO Ultrium Generation 5
Media
LTO Ultrium
Capacity
1500 GB (native) 3000 GB (compressed, assuming 2:1 compression)
Data transfer rate (maximum)
140 MB/sec Native
Burst transfer rate
up to 600 MB/sec for SAS
Operating Limits
Temperature
10°to38°C(50°to100°F)
Humidity
20% to 80% relative humidity (non-condensing)
Maximum wet bulb temperature
26°C(79°F)
Maximum altitude
3048 m (10,000 ft)
Non-operating Limits (Storage)
Temperature
-40°to60°(-40°to140°F)
Humidity
10% to 90% relative humidity (noncondensing)
Maximum wet bulb temperature
26°C(79°F)