Activate Storage Array Firmware
Description
This command activates firmware previously downloaded to the pending configuration area in the RAID controller
modules in the storage array.
Syntax
activate storageArray firmware
Parameters
None
Add Member To Consistency Group
Description
This command adds a new base virtual disk as a member to a an existing consistency group. You can specify an existing
repository virtual disk for the new consistency group member, or create a new repository virtual disk. When you create
a new repository virtual disk, you identify an existing disk group or an existing disk pool where you want the repository
virtual disk.
Syntax For Use With An Existing Repository Virtual Disk
set consistencyGroup ["consistencyGroupName"]
addCGMemberVirtualDisk="baseVirtualDiskName"
repositoryVirtualDisk="repositoryName"
Syntax For Use When Creating A New Repository Virtual Disk In A Disk Group
set consistencyGroup ["consistencyGroupName"]
addCGMemberVirtualDisk="baseVirtualDiskName"
repositoryVirtualDisk=("diskGroupName" capacity=capacityValue(KB|MB|GB|TB|
bytes))
Syntax For Use When Creating A New Repository Virtual Disk In A Disk Pool
set consistencyGroup ["consistencyGroupName"]
addCGMemberVirtualDisk="baseVirtualDiskName"
repositoryVirtualDisk=("
diskPoolName" capacity=capacityValue(KB|MB|GB|TB|bytes))