Owner manual

Syntax
set storageArray learnCycleDate
(daysToNextLearnCycle=
numberOfDays |
day=dayOfTheWeek) time=HH:MM
Parameters
Parameter Description
daysToNextLearnCycle
Valid values are 0 through 7, where, 0 is immediately and
7 is in seven days. The daysToNextLearnCycle
parameter takes place up to seven days after the next
scheduled learn cycle.
day
Valid values for the day parameter include the days of the
week. Setting the day causes the next learn cycle to be
scheduled on the specified day, after the currently
scheduled learn cycle.
time
The time in 24-hour format; for example 8:00 a.m. is
entered as 08:00. Nine o’clock p.m. is entered as 21:00, and
9:30 p.m. is entered as 21:30.
NOTE: You can set the learn cycle to occur only once during a seven-day period. The time parameter selects a
specific time that you want to run the learn cycle. If a value is not entered, the command uses a default value of
00:00 (midnight). If the day and time specified are in the past, the next learn cycle takes place on the next possible
day specified.
Set Storage Array Redundancy Mode
Description
This command sets the redundancy mode of the storage array to either simplex or duplex.
Syntax
set storageArray redundancyMode=(simplex | duplex)
Parameter
Parameter Description
redundancyMode
Use simplex mode when you have a single RAID controller
module. Use duplex mode when you have two RAID
controller modules
301