Owner manual

Parameter Description
replicationCacheEnabled
The setting to turn on or turn off the replication cache. To
turn on the replication cache, set this parameter to TRUE.
To turn off the replication cache, set this parameter to
FALSE.
modificationPriority
The priority for virtual disk modifications while the storage
array is operational. Valid values are highest, high,
medium, low, or lowest.
preReadConsistencyCheck
The setting to turn on or turn off preread consistency
checking. Turning on preread consistency checking
verifies the consistency of RAID redundancy data for the
stripes containing the read data. Preread consistency
checking is performed on read operations only. To turn on
preread consistency checking, set this parameter to
TRUE. To turn off preread consistency checking, set this
parameter to FALSE.
NOTE: Do not use this parameter on non redundant
virtual disks, such as RAID 0 virtual disks.
readCacheEnabled
The setting to turn on or turn off the read cache. To turn
on the read cache, set this parameter to TRUE. To turn off
the read cache, set this parameter to FALSE.
consistencyCheckEnabled
The setting to turn on or turn off the write cache. To turn
on the write cache, set this parameter to TRUE. To turn off
the write cache, set this parameter to FALSE.
segmentSize
The amount of data (in KB) that the controller writeson a
single physical disk in a virtual disk before writing data
onthe next physical disk. Valid values are 8, 16, 32, 64,
128, 256, or 512
userLabel
The new name that you want to give an existing virtual
disk. Enclose the new virtual disk name in double
quotation marks (" ").
writeCacheEnabled
The setting to turn on write cache capability.
Notes
When you use this command, you can specify one or more of the optional parameters.
You can apply these parameters to only one virtual disk at a time:
addCapacity
segmentSize
userLabel
310