Owner manual

Retrieve the performance modeling data using PowerVault MD Storage Manager.
Performance modeling ends, but no data is available when one of the following conditions occurs:
You reboot the RAID controller module.
You make any changes to the SSD cache configuration.
The state of the SSD cache changes.
Start Storage Array Blink
Description
This command identifies a storage array by turning on the indicator LED for the storage array. Use the stop
storageArray blink command to turn off the indicator LED for the storage array.
Syntax
start storageArray blink
Parameters
None.
Start Storage Array Configuration Database Diagnostic
Description
This command runs a consistency check against a configuration database.
Syntax
start storageArray configDbDiagnostic
[sourceLocation=(disk | onboard)]
[diagnosticType = (fileSystem | mirror | contentCheck)]
[controller[(0 | 1)]]
359