Administrator Guide

You also have the following options:
capacity of the SSD cache from a list of possible candidates consisting of different counts of SSD physical disks.
whether you want to enable SSD cache on all eligible virtual disks currently mapped to hosts
whether to use SSD cache on existing virtual disks or when creating new virtual disks
SSD cache restrictions
The following restrictions apply to using SSD cache feature:
SSD cache is not supported on Snapshot Virtual Disks.
If you import or export base virtual disks that are SSD cache enabled or disabled, the cached data is not imported or exported.
Maximum usable SSD cache capacity on a storage array is dependent on the RAID controller module’s primary cache capacity.
You cannot remove the last physical disk in an SSD cache without first deleting the SSD cache.
Only one SSD cache is supported per storage array.
If all the SSDs in the SSD cache are data assurance-capable and the data assurance (DA) feature is enabled, DA is automatically
enabled for the SSD cache and cannot be disabled.
You cannot add non-DA capable SSDs to a DA-enabled SSD cache.
Creating an SSD cache
1. In the AMW, select the Storage & Copy Services tab.
2. Do one of the following:
In the tree view, right click on SSD Cache and select Create.
From the menu bar, select Storage > SSD Cache > Create.
The Create SSD Cache window is displayed.
3. Type a name for SSD Cache name.
4. Select an I/O characteristic type from one of the following:
File System
Database
Web Server
5. Select an appropriate option for Data Assurance (DA).
6. Select an appropriate capacity from SSD cache candidates.
A maximum of 5,120 GB of SSD cache is available in the usable capacity.
NOTE:
To view the physical disks that comprise the usable capacity, select the appropriate row under SSD cache
candidates, and click View Physical Disks.
7. SSD Cache is enabled by default. To disable, click Suspend. To re-enable, click Resume.
8. Click Create.
Viewing physical components associated with an
SSD cache
To view the physical components associated with an SSD cache:
1. In the AMW, select the Storage & Copy Services tab.
2. In the tree view, select the SSD cache. and do one of the following:
From the menu bar, select Storage > SSD Cache > View Associated Physical Components.
Right click on the SSD cache and select View Associated Physical Components.
In the Table view for the SSD cache, click View Associated Physical Components.
The View Associated Physical Components window is displayed.
3. To view a physical disk type, select a disk type from Physical Disk Type and click Show.
To hide the displayed components, click Hide.
4. To view the components installed in the associated enclosure, click View Enclosure Components.
Using SSD cache
95