CLI Guide

Set Session
Description
This command defines how you want the current script engine session to run.
Syntax
set session errorAction=(stop | continue)
password=”storageArrayPassword
performanceMonitorInterval=intervalValue
performanceMonitorIterations=iterationValue
Parameters
Parameter Description
errorAction
How the session responds if an error is
encountered during processing. You can choose
to stop the session if an error is encountered, or
you can continue the session after encountering
an error. The default value is stop. (This parameter
defines the action for execution errors, not syntax
errors. Some error conditions might override the
continue value.)
password
The password for the storage array. Enclose the
password in double quotation marks (“ ”).
performanceMonitorInterval
The frequency of gathering performance data.
Enter an integer value for the polling interval, in
seconds, for which you want to capture data. The
range of values is 3 to 3600 seconds. The default
value is 5 seconds.
performanceMonitorIterations
The number of samples to capture. Enter an
integer value. The range of values for samples
captured is 1 to 3600. The default value is 5.
Additional Information
When you use this command, you can specify one or more of the optional parameters.
Passwords are stored on each storage array in a management domain. If a password was not previously
set, you do not need a password. The password can be any combination of alphanumeric characters with
a maximum of 30 characters. (You can define a storage array password by using the set storageArray
command.)
The polling interval and the number of iterations that you specify remain in effect until you end the
session. After you end the session, the polling interval and the number of iterations return to their default
values.
318