CLI Guide

Parameters
None
Notes
When you retrieve a controller health image from the RAID controller module cache to a host, a flag is
set on the RAID controller module to indicate that the controller health image does not need to be
retrieved. This setting persists for 48 hours. If a new controller health image occurs during that period,
the new controller health image is saved to the RAID controller module cache and overwrites any
previous controller health image data in the cache.
You can use the set storageArray controllerHealthImageAllowOverWrite command to set
the RAID controller module flag so that a new controller health image overwrites any previous controller
health image. Without retrieving a controller health image, this command sets the flag by default.
Clear Storage Array Event Log
Description
This command clears the Major Event Log (MEL) for the storage array by deleting the data in the
MEL buffer.
CAUTION: As soon as you run this command, the existing MEL in the storage array is deleted.
Syntax
clear storageArray eventLog
Parameters
None.
Clear Storage Array Firmware Pending Area
Description
This command deletes a previously downloaded firmware image or nonvolatile static random access
memory (NVSRAM) values from the pending area buffer.
CAUTION: As soon as you run this command, the contents of the existing pending area in the
storage array are deleted.
Syntax
clear storageArray firmwarePendingArea
155