CLI Guide

Saves a ZIP file containing raw binary data
The RAID controller module firmware saves the ZIP file to this location:...\Install_dir\data
\FirmwareUpgradeReports\timestamp_buildNo.zip
You can use the binary data to help determine the cause of the problem, or you can send the file
containing the binary data to a Technical Support representative.
To stop the database configuration diagnostic test, use the stop storageArray
configDbDiagnostic command.
In addition, you can start the database configuration diagnostic test through the MD storage
management software GUI; however, you cannot stop the database configuration diagnostic test
through the MD storage management software GUI. If you want to stop a running diagnostic test, you
must use the stop storageArray configDbDiagnostic command.
Start Storage Array iSCSI Refresh
Description
This command initiates a refresh of the network address information for the iSNS server. If the DHCP
server is marginal or unresponsive, the refresh operation can take from 2 to 3 minutes to complete.
NOTE: This command is for IPv4 only.
Syntax
start storageArray isnsServerRefresh
Parameters
None.
NOTE: If you used the set storageArray isnsIPv4ConfigurationMethod command to set
the configuration but did not set the configuration to DHCP, running the start storageArray
isnsServerRefresh
returns an error.
Start Virtual Disk Initialization
Description
This command starts the formatting of a virtual disk in a storage array.
NOTE: Initializing a virtual disk is a long-running operation that you cannot stop.
Syntax
start virtualDisk [virtualDiskName] initialize
399