CLI Guide

run VAAI, or if VAAI is causing issues with the storage array. The only storage array that is affected is the
storage array on which the command is run.
Syntax
set storageArray vaaiEnabled=(TRUE | FALSE)
Parameter
Parameter Description
vaaiEnabled
The setting to turn on or turn off VAAI. To turn on
VAAI set this parameter to TRUE. To turn off VAAI
set this parameter to FALSE. The default setting is
that VAAI is turned on.
NOTE: VAAI enables some storage tasks to be offloaded from the server hardware to a storage
array. Offloading the storage tasks to a storage array increases host performance by reducing the
tasks the host must perform.
Enable RAID Controller Module Data Transfer
Description
This command revives a RAID controller module that quiesces while running diagnostics.
Syntax
enable controller [(0 | 1)] dataTransfer
Parameter
Parameter Description
controller
RAID controller module that you want to revive.
Valid RAID controller module identifier values are 0
and 1. The identifier value is 0 for the RAID
controller module on the top and
1 for the RAID
controller module on the bottom when viewed
from the rear of the enclosure. You must put
brackets ([ ]) around the RAID controller module
identifier. If you do not specify a RAID controller
module, the MD storage management software
returns a syntax error.
Enable Storage Array Feature
Description
This command enables a premium feature using a feature key file.
234