Users Guide

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack
Dell PowerVault ML6000 User’s Guide 344
Installing the Bottom
Module in the Rack 12
Required parts: Rack ears, (4) M5 thumbscrews
Explanation of parts: Each rack ear contains two elongated holes, enabling
you to fasten it to the rack (using the M5 thumbscrews) in the most
accessible mounting holes.
1 Place the desired module (whichever module you want to be the
bottom module of the library) onto the rack-mount shelves. From the
front of the rack, lift the module onto the shelf and gently slide it into
the rack. Slide the module to the back of the rack, so that the front of
the module is flush with the mounting holes.
2 From the back of the rack, secure the module to the rack-mount
shelves by tightening the two silver thumbscrews that are attached to
the rear of the rack-mount shelves.
3 Install the right rack ear. At the front of the library:
a Open the I/E station door. At the lower right corner of the
module is a vertical slot. Insert the hinge of the right rack ear into
the slot and then position the holes of the rack ear flush with the
rack rail.
1 Hinge of rack ears