User's Manual

v Restore Passwords - This menu item restores the factory default for both the
RMU Admin user access password and the service password.
v Restore all - This menu item restores all factory default settings (refer to
Table 5-4).
v Restore Library Config - This menu item restores your saved library
configuration from a USB device. If you have more than one saved configuration
file (.dbb) on your USB device, press Select, then use the up and down keys to
move between the different files. When the correct configuration file is
displayed, press Select again.
v Save Library Config - This menu item saves your library configuration to a USB
device.
Note: Ensure the USB device is formatted for FAT12, FAT16, or FAT32 and does
not use autorun files.
Note: Configuration files saved with one version of library firmware may not be
compatible with other versions of firmware. It is recommended to save a
configuration file each time the library firmware is upgraded. Restore the
library using a configuration file that was saved with the same version of
firmware currently installed in the library.
Important: Restoring factory defaults will wipe out all the previous configuration
data. Factory defaults must be restored when the library drive is changed from a
LTO half height to full height configuration, in order for the library to correct the
element addressing and drive numbering. If a new drive is added to the library
configuration, a restore factory default is not required.
Table 5-4. Factory Default Settings
Restored Item Default Setting* Comments
Autoclean Disabled
Logical Libraries 1
Active Slots Maximum number of slots in library
minus I/O Station
I/O Station Enabled 2U library has 1-slot I/O Station.4U
library has 3-slot I/O Station.
Encryption None License Key is protected, if
previously entered.
Ethernet Setting Auto
Configure
Save/Restore
a77ug045
Restore All Restore Library Config.Restore Passwords Save Library Config.
Figure 5-19. Configure: Save/Restore menu
Chapter 5. Operations 5-27