User's Manual

Note: When reducing the number of drives in your library, update the Logical
Library configuration. This will remove the Attention LED on the front
panel and the exclamation mark on the Home screen indicating that a drive
is missing.
Updating the Logical Library configuration will also update the drive element
addressing and drive numbering. Replacing LTO half height drives with full height
drives may require you to execute Restore Factory Defaults to correctly update the
drive element addressing and drive numbering. See “Configure Library:
Save/Restore Configuration” on page 5-57.
Configure Library: Path Failover
This page allows the user to enter the Path Failover feature activation key
(Supported on 4U library only for library firmware levels at or below 8.xx.
Supported on both the 2U and 4U libraries with library firmware levels above 8.xx)
For library firmware levels below 8.xx the Path Failover feature is available for
select LTO 4 tape drives, and Path Failover is not supported for Half Height
drives. Library firmware levels higher than B.50 support Path Failover on LTO 6
drives. Library firmware levels higher than 8.xx support Path Failover on LTO 5
drives, as well as LTO 4 Full Height drives. For more information, refer to the Dell
PowerVault TL4000 Failover Configuration Guide, included with the library
documentation.
Enter the Feature Activation key and click Activate. This page will display if you
have entered the feature key correctly.
a77ug0
98
Figure 5-36. The 4U library Configure Library: Logical Libraries page
a77ug117
Figure 5-37. The 4U library Configure Library: Path Failover page
Figure 5-38. Path Failover license verification page
Chapter 5. Operations 5-45