CLI Guide

11.3.2 Cartridge Storage Conditions
Before you use a cartridge, let it acclimate to the normal operating environment for 24 hours.
Ensure that all surfaces of the cartridge are dry before use.
Do not expose the cartridge to moisture or direct sunlight.
Always ship or store a cartridge in the vertical orientation and inside a jewel case to prevent
damage to the tape edge.
Do not expose recorded or blank cartridges to stray magnetic fields (for example, terminals,
motors, video equipment, X-ray equipment, or fields that exist near high-current cables or power
supplies). Such exposure can lead to loss of data or render the blank cartridge unusable.
Maintain the environmental conditions outlined in the Table 15.
Table 15 Cartridge Storage Conditions
Environmental
Factor
Operating Operational
Storage
Archival
Storage
Shipping
Temperature
10
°
C to 45
°
C (50
°F to 113 °F)
16 °C to 32 °C (61
°F to 90 °F)
16
°
C to (61 °F to
77 °F) 25 °C
-23
°
C to 49
°
C (-9 °F
to 120 °F)
Relative humidity
(non-condensing)
10 % to 80 % 20 % to 80 % 20 % to 50 % 5 % to 80 %
Wet bulb
temperature
26
°
C
(79 °F)
26
°
C
(79 °F)
26
°
C
(79 °F)
26
°
C
(79 °F)
11.4 Cartridge Life
Durability 1,000,000 passes on any area of tape, equates to over 20,000 end-to-end passes/260
full tape backups.
Archival life 30 years.
27 Dell PowerVault Tape Systems | A05