CLI Guide
11.3.2 Cartridge Storage Conditions
• Before you use a cartridge, let it acclimate to the normal operating environment for 24 hours.
• Ensure that all surfaces of the cartridge are dry before use.
• Do not expose the cartridge to moisture or direct sunlight.
• Always ship or store a cartridge in the vertical orientation and inside a jewel case to prevent
damage to the tape edge.
• Do not expose recorded or blank cartridges to stray magnetic fields (for example, terminals,
motors, video equipment, X-ray equipment, or fields that exist near high-current cables or power
supplies). Such exposure can lead to loss of data or render the blank cartridge unusable.
• Maintain the environmental conditions outlined in the Table 15.
Table 15 Cartridge Storage Conditions
Environmental
Factor
Operating Operational
Storage
Archival
Storage
Shipping
Temperature
10
°
C to 45
°
C (50
°F to 113 °F)
16 °C to 32 °C (61
°F to 90 °F)
16
°
C to (61 °F to
77 °F) 25 °C
-23
°
C to 49
°
C (-9 °F
to 120 °F)
Relative humidity
(non-condensing)
10 % to 80 % 20 % to 80 % 20 % to 50 % 5 % to 80 %
Wet bulb
temperature
26
°
C
(79 °F)
26
°
C
(79 °F)
26
°
C
(79 °F)
26
°
C
(79 °F)
11.4 Cartridge Life
• Durability – 1,000,000 passes on any area of tape, equates to over 20,000 end-to-end passes/260
full tape backups.
• Archival life – 30 years.
27 Dell PowerVault Tape Systems | A05