Administrator Guide

Parameters
Table 14. List power supply devices
Parameter Description
-a
Specify the adapter used for the command. This can be either
SAS WWID or AdapterIndex.
-enc
Specify the enclosure used for the command. This is either
WWN or EnclIndex.
-h
Provides more information about the command, description,
and usage.
-outputformat
You can specify the following output formats: xml or json.
Command examples
list power supplies -a = 1 -enc = 500a123456789012
list power supplies -a = 1 -enc = 0
list power supplies -enc = 500a123456789012 -outputformat = xml
List temperature sensors
Description
This command lists the temperature sensors accessible from the specified enclosure.
Command syntax
shmcli (list temp sensors | listtemperaturesensors | lts) (-a=<(SAS WWID |
AdapterIndex)> -enc=<(WWN | EnclIndex)> [-outputformat<SupportedOutputFormats>]
| -enc=<WWN> [-outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 15. List temperature sensors
Parameter Description
-a
Specify the adapter used for the command. This is either SAS
WWID or AdapterIndex.
-enc
Specify the enclosure used for the command. This is either
WWN or EnclIndex.
-h
Provides more information about the command, description,
and usage.
-outputformat
You can specify the following output formats: xml or json.
Command examples
list temp sensors -a = 1 -enc = 500a123456789012
list temp sensors -a = 1 -enc = 0
list temp sensors -enc = 500a123456789012 -outputformat = xml
28