Administrator Guide
• AC power failure
• DC power failure
• Drawer
• Drawer is opened (warning)
• Drawer control module has failed
• EMM is removed
• EMM is connected
• Drive removed
• Drive is flagged as predicted to fail (SMART)
• Adapter PHY connection status change
• Adapter PHY link rate value change
• Drive is installed (warning)
• Physical Enclosure is connected
• Physical Enclosure is removed
• Fan state change (warning)
• Fan state is critical
• Current sensor is in 'critical' status
JBOD LEDs
The Server Hardware Manager monitoring tool provides the capability to automatically set LED behavior for the 3060e enclosure to
indicate drive predicted failure or drive failure. By default, the behavior is turned off.
To turn the behavior on and off:
1. Open the SHM.config file located in the binary folder of the installation.
• In Windows, the file is located at: Program Files\Dell\ServerHardwareManager
\ServerHardwareManagerMonitor.
• In Linux, the file is located at: /opt/dell/ServerHardwareManager/bin.
2. Under the [SHMSYSTEM] section of the file, add or edit the entry 3060eLEDControl.
• To turn the behavior on: 3060eLEDControl=ON.
• To turn the behavior off: 3060eLEDControl=OFF.
NOTE:
If the 3060eLEDControl item is missing or blank, the behavior by default is off.
3. Save the file.
4. Restart the monitoring service.
If the LED control behavior is turned on, the following LED control will occur:
1. If a drive is reporting a predicted failure state:
a. The drive slot LED will be set to the Identify state.
b. The enclosure LED will be set to the Failure state.
2. If a drive is determined to be in a failed state:
a. The drive slot LED will be set to the Failure state.
b. The enclosure LED will be set to the Failure state.
40
Monitoring