Owners Manual
Figure 40. Installing a Cooling Fan Module
5 Wait for the expansion enclosure to recognize the cooling fan module and determine its status.
6 Push the expansion enclosure chassis back into the rack.
7 In Storage Manager, make sure that the cooling fan module is recognized and shown as up and running.
Next steps
1 Use SupportAssist to send diagnostic data to technical support.
2 Change the operation mode of the Storage Center to Normal.
Enclosure Management Module
The SC460 expansion enclosure supports redundant hot-swappable enclosure management modules (EMMs).
EMMs provide the following management functions for the expansion enclosure:
• Monitoring and controlling expansion enclosure environment elements such as temperature, fan, power supplies, and expansion
enclosure LEDs
• Controlling access to hard drives
• Communicating expansion enclosure attributes and states to Storage Center
Identifying the Failed Enclosure Management Module
To determine which enclosure management module (EMM) failed, use the Storage Manager.
1 Click the Hardware tab.
2 In the Hardware tab navigation pane, select and expand the Storage Center.
3 In the Hardware Alerts area, nd the hardware alert that identies the expansion enclosure with the failed EMM.
Replacing SC460 Expansion Enclosure Components
41