Install Guide

Configure Hyper-V hosts to access SC Series arrays with SAS FE ports
20 Dell EMC SC Series Storage with SAS Front-end Support for Microsoft Hyper-V | 3026-CD-WS | V3
Note: The default driver installed by Windows may not be the correct driver or may be outdated. It is
important to install the latest driver available from Dell EMC. Verify that the HBA firmware is current when the
Windows driver is updated.
5. Repeat steps 14 to install SAS HBAs in additional Windows host servers. Verify that the SAS HBA
firmware and drivers are current on all hosts before continuing.
3.3 Configure SAS FE fault domains to support MPIO hosts
An SC5020 array is used in this example to show how to complete the configuration. The configuration steps
for other SC arrays with SAS FE are similar.
1. Launch the Dell EMC Storage Manager Client and connect to the SC Series array directly or to a
Data Collector. In this example, the connection is made directly to the SC5020 by entering the
management IP address.
2. Click Storage > Fault domains. In this example, no fault domains are configured on the SC5020.
Click Front End SAS Port Configuration to start the configuration wizard.