Table 8. Peripheral Settings for wnos.ini Files, {username} INI, and $MAC INI files (continued)
Parameter
* Global overrides identically-named user profile
** After sign off, user profile returns to global value
Description
[CloseLidCharge={No, ShutDown, OffDisplay}]
[CloseLidDisCharge={No, ShutDown, OffDisplay}]
[BatteryAutoPowerOff={3-20}]
TrackpadDisable={yes, no}Default value is no. The
Yes/No option enables or disables the trackpad.
[CloseLidCharge={No, ShutDown, OffDisplay}]This
parameter is applicable for the Wyse 5470 Thin Client. This
option specifies the thin client behavior when you close the lid
of the thin client connected to an external power source and
not running on battery.
The following are the values that you can set for
CloseLidCharge:
NoOnly the built-in display is turned off and any external
displays connected to the thin client are turned on when
the lid is closed.
ShutDownThe thin client shuts down when the lid is
closed.
OffDisplayThe built-in display and any external displays
connected to the thin client are turned off when the lid is
closed. This is the default value.
[CloseLidDisCharge={No, ShutDown, OffDisplay}]-This
parameter is applicable for the Wyse 5470 Thin Client. This
parameter specifies the thin client behavior when you close
the lid of the thin client running on battery and not connected
to any external power source.
The following are the values that you can set for
CloseLidDisCharge:
NoOnly the built-in display is turned off and any external
displays connected to the thin client are turned on when
the lid is closed.
ShutDownThe thin client shuts down when the lid is
closed. This is the default value.
OffDisplayThe built-in display and any external displays
connected to the thin client are turned off when the lid is
closed.
[BatteryAutoPowerOff={3-20}This parameter is
applicable to the Wyse 5470 Thin Client when it is on low
battery.
This option specifies that the device shuts down if battery
capacity is lower than your set value. The value margin is 3
20 and the unit is percentage.
LpdSpool={0-50}
Specifies the size of spool to buffer all the data before
sending them to the LPD printer. The range of value is 010,
that is, 0 MB to 10 MB. If the specified value is above the
range, then the value is set to 5.
The range of value is extended to 50.
In build 8.2_001 or later builds, the LPD data is spooled to a
file in a ram disk instead of a buffer. So the value of the
parameter will not be related to the spool size as before.
If LpdSpool=0, the function is disabled, otherwise the function
is enabled.
LPTPortBind={yes, no}
LPTPortBind Default is Yes. Specifies the LPT bind to the
USB Port Policy.
66 Parameters for wnos INI, {username} INI, and $MAC INI files