Specifications

69
Example: 0 = min. current, 255 = max. current
FUNCTION 5 PLUGGING DISTANCE (CURRENT)
( Push 5 )
This function allows for the adjustment of the plugging
distance of the vehicle. The larger the current setting, the
shorter the stopping distance.
Range 200 to 1000 amps (EV100)
300 to 1500 amps (EV200)
Set 0 to 255
Resolution 3.14 amps per set unit (EV100)
4.7 amps per set unit (EV200)
Example: Setting of 20 = 263 amps (EV100)
Warning: Plug settings must be in accordance with
control operating instructions. An excessively high set-
ting could cause damage to control system or traction
motor.
FUNCTION 6 1A DROP OUT CURRENT
( Push 6 )
This function allows for the adjustment of the 1A contactor
drop out current. The 1A contactor will be dropped out and
the vehicle motor torque will be limited to SCR current limit
when the set drop out current is reached.
Range 450 to 1260 amps (EV100)
675 to 1890 amps (EV200)
Set 0 to 250
Resolution 3.24 amps per set unit (EV100)
4.86 amps per set unit (EV200)
Settings above 250 set units will disable 1A drop out function
( 1A will not drop out).
Example Setting of 20 = 515 amps (EV100)
FUNCTION 7 FIELD WEAKENING PICK UP
( Push 7 )
This function allows the adjustment of field weakening
contactor pick up current. This setting allows the FW
contactor to pick up when the vehicle has returned to about
150% of its full load level running current after acceleration.
Range 52 to 466 amps (EV100)
78 to 699 amps (EV200)
Set 0 to 255
Resolution 1.6 amps per set unit
2.4 amps per set unit
Example Setting of 20 = 84 amps
DESCRIPTION OF FUNCTION NUMBERS FOR:
Control Cards IC3645EVLXCD1TT AND
IC3645EVLXCD1TX
FUNCTION 1 STORED FAULT CODE
( Push 1)
This function register contains the last fault that shut down
vehicle operation ( PMT type fault that is reset by cycling the
key switch ) . This fault code will be over written each time
a new fault occurs and can be cleared from memory by
adjusting the value to zero.
FUNCTION 2 CREEP SPEED
( Push 2 )
This function allows for the adjustment of the creep speed of
the vehicle. A constant creep speed frequency will be main-
tained when an accelerator input voltage between 3.7 and 3.5
volts or an accelerator ohmic input between 6K and 4.7K
ohms is provided.
Range 2% to 15% on time
Set 0 to 255
Resolution .03% per set unit
Example: Setting of 20 = 2.6% on time
FUNCTION 3 CONTROLLED ACCELERATION
AND 1A TIME
( Push 3 )
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 96% applied battery
voltage to the motor on hard acceleration. The 1A contactor
will automatically close .2 seconds after the controlled
acceleration stops and the accelerator input is less than .5
volts or less than 50 ohms.
Range .1 to 22.0 seconds
Set 0 to 255
Resolution .084 seconds per set unit
Example: Setting of 20 = 1.8 seconds C/A
and 2.0 1A time.
FUNCTION 4 CURRENT LIMIT
( Push 4 )
This function allows for the adjustment of the current limit
of the control. The rating of the control will determine the
range of adjustment for this function. Please refer to the
operating instructions for the control used in your vehicle.
Range See control C/L curves
Set 0 to 255