Specifications

75
DESCRIPTION OF FUNCTION NUMBERS FOR:
Control Card IC3645EVLXCD1PX
FUNCTION 1 STORED FAULT CODE
( Push 1)
This function register contains the last status code that shut
down vehicle operation ( PMT type fault that is reset by
cycling the key switch ) . This status code will be over written
each time a new fault occurs and can be cleared from memory
by adjusting the value to zero.
FUNCTION 2 INTERNAL RESISTANCE
COMPENSATION START
( Push 2 )
This function allows for the adjustment of the current level
at which the internal resistance compensation feature (Func-
tion 16) will take effect.
Range 0 to 1325 amps
Set 52 to 255
Resolution 6.5 amps per set unit
Example: Setting of 72 = 130 amps
FUNCTION 3 CONTROLLED ACCELERATION
AND 1A TIME
( Push 3 )
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 96% applied battery
voltage to the motor on hard acceleration. The 1A contactor
will automatically close .2 seconds after the controlled
acceleration stops and the accelerator input is less than .5
volts or less than 50 ohms.
Range .1 to 5.5 seconds
Set 0 to 255
Resolution .021 seconds per set unit
Example: Setting of 20 = .52 seconds C/A
and .72 seconds 1A time.
FUNCTION 4 CURRENT LIMIT
( Push 4 )
This function allows for the adjustment of the current limit
of the control. The rating of the control will determine the
range of adjustment for this function. Please refer to the
operating instructions for the control used in your vehicle.
Range See control C/L curves
Set 0 to 255
Example: 0 = min. current, 255 = max. current
FUNCTION 11 SPEED LIMIT 1 (SL1)
( Push 11 )
This function allows for the adjustment of the speed limit (
maximum battery volts to the motor ) when the SL1 limit
switch input signal is received by the control card. SL1 limit
switch is a normally open switch connected to battery
negative, the switch closing enables speed limit.
Range 0% to 100% battery volts
Set 0 to 255
Resolution .375 volts per set unit
Example Setting of 50=18.75 volts
FUNCTION 12 SPEED LIMIT 2 (SL2)
( Push 12 )
Same as Function 11 except using SL2 limit switch for input.
FUNCTION 13 SPEED LIMIT 3 (SL3)
( Push 13 )
Same as Function 11 except using SL3 limit switch for input.
FUNCTION 14 SPEED LIMIT 4 (SL4)
( Push 14 )
Same as Function 11 except using SL4 limit switch for input.
The following functions have function numbers larger
than the numbers on the handset keyboard. To access these
functions, push the CONT key and the number shown in
the following instructions at the same time.
FUNCTION 16 SPEED / TORQUE
COMPENSATION
( Push CONT and 1 )
This function is used to stabilize pump speed at heavy loads.
This function is set using information obtained from the
speed torque curve of the motor used. See OEM service
manual for your vehicle for this setting.
SPEED / TORQUE COMPENSATION
TABLE
Setting Voltage Drop Setting Voltage Drop
2 11.44 17 01.34
3 07.60 18 01.27
4 05.72 19 01.20
5 04.57 20 01.14
6 03.81 21 01.09
7 03.27 22 01.04
8 02.86 23 00.99
9 02.54 24 00.95
10 02.28 25 00.91
11 02.08 26 00.88
12 01.90 27 00.85