Specifications

76
Setting Voltage Drop Setting Voltage Drop
13 01.76 28 00.82
14 01.63 29 00.79
15 01.52 30 00.76
16 01.43 31 00.74
FUNCTION 17 CARD TYPE SELECTION
( Push CONT and 2 )
This function allows for the selection of the card type used for
your vehicles application. The table below shows the setting
to select card application type depending on which control
card is used.
With Pump Without Pump
Function Ctr/PMT Ctr/PMT
STD C/L 0 to 8 36 to 44
High C/L 9 to 17 45 to 53
STD C/L
BDI (Lockout) 18 to 26 54 to 62
High C/L
BDI (Lockout) 27 to 35 63 to 71
BDI Lockout means that the BDI signal from the traction
control must be present in order for the pump control to
operate. This control will stop operation when the battery
state of charge reaches 10%.
Settings for these functions should be made in between the
values shown.
Warning: These setting must be changed by authorized
personnel only, following instructions supplied by the
manufacturer. Card type selection must be made within
the capabilities of the SCR control panel used and the
supporting electro-mechanical devices. Failure to com-
ply with proper application standards could result in
misoperation or damage to the control and/or motors.