DELTA HEAT TEPPANYAKI GRIDDLE INSTALLATION, USE, & CARE MANUAL P/N: 17634A 02/21 MODELS: DHTG32
IMPORTANT SAFETY INSTRUCTIONS WARNING! Read this manual carefully and completely before using your Teppanyaki Griddle to ensure proper operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or other injury.
A Special Message to our Customers... Congratulations on your purchase of Delta Heat Teppanyaki Griddle. Delta Heat is committed to making outdoor cooking products you’ll be proud to own for years. This manual gives you easy to follow instructions for installing, operating and maintaining your Delta Heat Teppanyaki Griddle. We recommend reading this manual carefully before your first use to ensure safety, proper care and operation.
GENERAL SAFETY REQUIREMENTS • • • • • • • • • • • The installation of this appliance must conform with local codes or, in the absence of local codes, either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 or Propane Storage and Handling Code, B149.
TABLE OF CONTENTS GETTING STARTED GAS SAFETY REQUIREMENTS LP GAS HOOK-UP PORTABLE LP CONNECTION NATURAL GAS INSTALLATION LEAK TEST ELECTRICAL REQUIREMENT WIRING DIAGRAM BURNER FLAME / AIR SHUTTER ADJUSTMENT LOCATING THE TEPPANYAKI GRIDDLE TEPPANYAKI GRIDDLE CUT-OUT DIMENSIONS INSULATION JACKET OPERATING INSTRUCTIONS CLEANING & MAINTENANCE EXPLODED VIEW REPLACEMENT PARTS LIST WARRANTY HOW TO OBTAIN SERVICE 1 2 3 4-5 6 7 8 9 10 11 12 13 14 15-17 18 19 20 21
GETTING STARTED Safe and satisfactory operation of the Teppanyaki Griddle depends upon its proper installation. The installation, adjustments and service of the Griddle must be performed only by a qualified installer and service technician. Proper location and proper use is essential to insure safe and continued trouble-free operation. Any alterations made to the appliance will void the product’s warranty. Before installing, check the rating/serial plate of the Teppanyaki Griddle.
GAS SAFETY REQUIREMENTS Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of gas, either Natural Gas or LP gas and make sure that the marking on the rating/serial plate matches the gas being supplied to the Teppanyaki Griddle. All gas connections should be made by a qualified technician and in accordance with local codes and ordinances.
LP GAS HOOK-UP Install the factory-supplied hose and regulator assembly as shown. Connect the 3/8” flare end of the hose to the grill coupling using a 3/4” open wrench. Do not apply pipe sealant to the 3/8” flare connection. Connect the regulator to the LP cylinder hand tighten it, do not use a wrench. Check for leaks using soapy water solution. (Reference page X for leak test procedure).
PORTABLE LP CONNECTION FOR CART APPLICATIONS An enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP cylinder in place. This shall be accomplished by one of the following: a. one side of the enclosure shall be completely open; or b. for a cylinder enclosure having four sides, a top and a bottom: i.
PORTABLE LP CONNECTION NOTE: USE ONLY A 20-LBS. (5-GALLON CAPACITY) GAS CYLINDER. WARNING: DO NOT PLACE MORE THAN ONE CYLINDER IN THE BASE CABINET ENCLOSURE AT ANY TIME. WARNING: DO NOT USE A DENTED OR RUSTED LP CYLINDER. NEVER USE A CYLINDER WITH A DAMAGED VALVE. ALWAYS CHECK FOR LEAKS AFTER CHANGING THE LP CYLINDER. (Page 7) THE LP PRESSURE REGULATOR AND HOSE SUPPLIED WITH THIS UNIT MUST BE USED WITHOUT ALTERATION. ALWAYS USE THE TANK SECURING DEVICE SUPPLIED WITH GRILL BASE. 1.
NATURAL GAS INSTALLATION The installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 or Propane Storage and Handling Code, B149.2. 1. This gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at the test pressures in excess of 1/2 psi (3.5 kPa). 2.
LEAK TEST CAUTION BEFORE TESTING • Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure. • NEVER USE THE TEPPANYAKI GRIDDLE WITHOUT FIRST LEAK TESTING THE GAS CONNECTIONS. • WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN FLAME COULD RESULT IN A FIRE, EXPLOSION, BODILY HARM OR DEATH. • DO NOT SMOKE WHILE PERFORMING THE LEAK TEST! • To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while performing a leak test.
ELECTRICAL REQUIREMENT TO INSTALL AND SECURE POWER TRANSFORMER The Teppanyaki Griddle is equipped with LED lights that require the use of a power transformer with an attached power supply cord. This transformer must be secured in a dry location and away from the Teppanyaki Griddle firebox and excessive heat area. a. In a base cart application, four mounting screws with nuts are provided at the bottom left rear corner of the cart. If not provided, drill four holes using the transformer box as a template.
WIRING DIAGRAM This Delta Heat product is provided with electrical components, proper handling and care is needed to maintain the quality of your Delta Heat product. 1. To protect against shock, do not immerse cord or plug in water or other liquid; 2. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts; 3.
BURNER FLAME / AIR SHUTTER ADJUSTMENT Each Teppanyaki Griddle burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the U-burners should be visually checked. Flames should be blue and stable with little to no yellow tips, no excessive noise or lifting.
LOCATING THE TEPPANYAKI GRIDDLE This gas appliance is designed and certified for outdoor use only. Do not locate this appliance under unprotected overhead combustible surfaces. When installed under overhead combustible surfaces, a certified ventilating hood wider than the appliance shall be installed with a minimum distance of 36 inches above the cooking surface. NOTE: Caution should be taken when the Teppanyaki Griddle is used near glass, vinyl siding or other temperature sensitive construction materials.
TEPPANYAKI GRIDDLE CUT-OUT DIMENSIONS THESE DIMENSIONS ARE FOR NON-COMBUSTIBLE CONSTRUCTION ONLY. FOR COMBUSTIBLE CONSTRUCTION SEE NEXT PAGE. 32 20.50 DHTG32 30.50 19.75 9.50 DETAIL 19.75 WIDTH OF UNIT COUNTERTOP OVERHANG NOTE: DETAIL IS TYPICAL TO ALL DH CUT-OUTS. 12 | www.deltaheat.
INSULATION JACKET 32 36.68 20.50 22.25 11.00 35 21.50 10.50 WARNING Do not build the grill under overhead combustible construction. If the grill is to be placed into combustible enclosure, an approved insulating jacket is necessary to prevent fire, property damage and bodily injury. Use only Delta Heat (DHIJ32) insulating jacket. IMPORTANT If using LP gas cylinder and insulation jacket (DHIJ), use stainless flexible hose to connect LP gas cylinder to grill regulator.
OPERATING INSTRUCTIONS Lighting Instructions 1. Ensure the Gas supply valve is closed and the burner knob is set to the OFF position. 2. Open the valve on the gas supply. 3. Push and turn the knob counterclockwise to the HIGH position. You will hear the spark igniter come on. Keep the knob pushed in for a minimum of 30 seconds to ensure the burner remains lit. 4. To shut down, turn the knob to the OFF position. 5. For complete shutdown, close the valve at the gas supply. Manual Ignition 1.
CLEANING & MAINTENANCE General Overview Proper care, maintenance, and cleaning will help ensure a long life of your Teppanyaki Griddle. Periodic cleaning will help avoid accumulations of flammable grease, fats, and other debris. Some debris and residue may remain on the griddle plate. To remove this residue after cooking, simply dip a brass-bristle brush in tap water and scrub the hot plate. Caution: Always allow the Teppanyaki Griddle to cool before cleaning.
CLEANING & MAINTENANCE - CONT. In the event that surface corrosion has developed on the stainless steel, it is typically not the stainless steel that is corroding but corrosive particles that have been deposited on the surface. WARNING: It is recommended that your Delta Heat products be kept dry and covered when not in use. This is even more important when long-term storage is intended.
CLEANING & MAINTENANCE - CONT. SPIDER AND INSECT WARNING Spiders and other insects can nest in the burners of this and any other Delta Heat gas appliances, which causes the gas to flow from the front of the burner. This dangerous “condition” can cause a fire behind the valve panel, damaging the gas appliance and making it unsafe to operate. Inspect the burners once a year or if the gas appliance has not been used for more than one month or if any of the following conditions occur: 1.
EXPLODED VIEW 18 | www.deltaheat.
REPLACEMENT PARTS LIST ITEM NO. DH PART NO. 1 S23375-32Y 2 S23389-32WY 3 DESCRIPTION QTY.
WARRANTY LIMITED LIFETIME WARRANTY: Delta Heat warrants the stainless steel main burners and all fabricated stainless steel components, to be free from defects in materials and workmanship under normal residential use for the lifetime of the product. This warranty excludes discoloration, surface scratches, weather and atmospheric related staining, and minor surface rust and oxidation which are normal conditions and are to be expected with any outdoor product.
HOW TO OBTAIN SERVICE For service, please contact your DELTA HEAT dealer or call DELTA HEAT direct at (562) 263-3600 or (800) 422-0091 or fax (562) 802-3391 Mailing address: DELTA HEAT, Inc. 13259 166th Street Cerritos, CA 90703 Visit us at www.deltaheat.
CUT HERE PLACE POSTAGE HERE Customer Service ATTN: Warranty Department 13259 166th Street Cerritos, CA 90703 Service Direct Line: (562) 263-3600 Fax: (562) 801-3391