User Manual

Delta Heat Service (562) 263-3600 | 5
NOTE: USE ONLY A 20-LBS. (5-GALLON CAPACITY) GAS CYLIN-
DER.
WARNING: DO NOT PLACE MORE THAN ONE CYLINDER IN THE
BASE CABINET ENCLOSURE AT ANY TIME.
WARNING: DO NOT USE A DENTED OR RUSTED LP CYLINDER.
NEVER USE A CYLINDER WITH A DAMAGED VALVE.
ALWAYS CHECK FOR LEAKS AFTER CHANGING THE LP CYLIN-
DER. (Page 7)
THE LP PRESSURE REGULATOR AND HOSE SUPPLIED WITH
THIS UNIT MUST BE USED WITHOUT ALTERATION.
ALWAYS USE THE TANK SECURING DEVICE SUPPLIED WITH
GRILL BASE.
1. To install the gas cylinder, place the cylinder onto the provided cutout.
2. Check to ensure that the tank’s gas valve on top of the cylinder is closed.
3. Connect the LP regulator (included) to the cylinder and hand-tighten only. Open the tank valve
and make sure all connections are leak tight using a soapy water solution and a brush. (Refer-
ence page 7 for leak test procedure).
WARNING
DO NOT STORE SPARE LP GAS CYLINDER UNDER OR NEAR THIS APPLIANCE.
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
FAILURE TO DO SO, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR
PORTABLE LP CONNECTION