User's Manual

Table Of Contents
16-Axis MACRO CPU User Manual
64 How to use the 16-Axis MACRO CPU
NodeCntrlCmd: (Sent by Master - Located in Turbo at: Y:$3440 .. Y:$347F / Y-portion of Flag
Address)
Bit Function
0
* Position Capture (Triggered Event) Enable Flag
1 Not Used
2 Not Used
3 Not Used
4 Not Used
5 Not Used
6 Not Used
7 Not Used
8 Reserved for future ring protocol control
9 Reserved for future ring protocol control
10 Reserved for future ring protocol control
11
* Position Capture (Triggered Event) Enable Flag
12 Node Reset Command
13
This Slave detected a MACRO Ring Break (MRB) & became a Synchronizing Master
14
* Real-time Data or Amp. Enable
15
When B13 = 1 then B15 = 1 & is a Station Fault.
16 Reserved for future ring protocol control
17 Reserved for future ring protocol control
18 Reserved for future ring protocol control
19 Fast User Defined Command Flag (UserCmd1)
20 Fast User Defined Command Flag (UserCmd2)
21 Fast User Defined Command Flag (UserCmd3)
22 Fast User Defined Command Flag (UserCmd4)
23 Fast User Defined Command Flag (UserCmd5)
Note: The items in bold are reserved and defined flag locations.